FRA 213D SW4

Application and Description

These cables are designed for flexible installations, inside and outside railway rolling stock.

Standards

DIN 5510-2

Construction

  • Inner conductor: Stranded silver plated copper

  • Insulation: Crosslink PE (PEX)

  • Outer conductor (shield 1): Silver plated copper

  • Outer conductor (shield 2): Silver plated copper

  • Sheath: LSZH Elastomer

Electrical Characteristics at 20℃

Impedance

Ω

50+/-2

Nominal Capacitance

pF/m

101

Minimum Insulation Resistance

MΩ.km

100000

Inner Conductor Resistance

MΩ/km

5.8

Outer Conductor Resistance

MΩ/km

4.43

Attenuation

 

 

@10MHz

dB/100m

2

@50MHz

dB/100m

5

@100MHz

dB/100m

8

@150MHz

dB/100m

10

@200MHz

dB/100m

12

@300MHz

dB/100m

15

@400MHz

dB/100m

17

@450MHz

dB/100m

19

@500MHz

dB/100m

20

@600MHz

dB/100m

22

@800MHz

dB/100m

27

@850MHz

dB/100m

28

@900MHz

dB/100m

29

@950MHz

dB/100m

30

@1000MHz

dB/100m

31

@1800MHz

dB/100m

45

@1900MHz

dB/100m

47

@2000MHz

dB/100m

49

@2400MHz

dB/100m

55

@3000MHz

dB/100m

64

@4000MHz

dB/100m

79

@5000MHz

dB/100m

93

@6000MHz

dB/100m

106

Velocity of propagation

%

66

Mechanical and Thermal Properties

Minimum Bending Radius

50mm (static)

Temperature Range

-40℃~ +105℃

Technical Data

Conductor Construction

Nominal Inner Conductor Diameter

Nominal Outer Conductor Diameter

Nominal Overall Diameter

Nominal Weight

No/mm

mm

mm

mm

kg/km

7/0.75

2.25

8.7

10.8

202