Anhui Feichun Special Cable Co.,Ltd Email: Li.wang@feichuncables.com

FRA 316 SW4
Application and Description
These cables are designed for flexible installations, inside and outside railway rolling stock.
Standards
DIN 5510-2
Construction
Inner conductor : Stranded silver plated copper
Insulation : PTFE
Outer conductor (shield 1) : Silver plated copper
Outer conductor (shield 2) : Silver plated copper
Sheath : LSZH Elastomer
Electrical Characteristics at 20℃
Impedance | Ω | 50+/-2 |
|---|---|---|
Nominal Capacitance | pF/m | 94.5 |
Minimum Insulation Resistance | 100000 | |
Inner Conductor Resistance | MΩ/km | 29.9 |
Outer Conductor Resistance | MΩ/km | 7.5 |
Attenuation |
|
|
@10MHz | dB/100m | 7 |
@50MHz | dB/100m | 17 |
@100MHz | dB/100m | 24 |
@150MHz | dB/100m | 30 |
@200MHz | dB/100m | 35 |
@300MHz | dB/100m | 44 |
@400MHz | dB/100m | 52 |
@450MHz | dB/100m | 56 |
@500MHz | dB/100m | 59 |
@600MHz | dB/100m | 66 |
@800MHz | dB/100m | 78 |
@850MHz | dB/100m | 81 |
@900MHz | dB/100m | 83 |
@950MHz | dB/100m | 86 |
@1000MHz | dB/100m | 89 |
@1800MHz | dB/100m | 127 |
@1900MHz | dB/100m | 131 |
@2000MHz | dB/100m | 135 |
@2400MHz | dB/100m | 152 |
@3000MHz | dB/100m | 175 |
@4000MHz | dB/100m | 211 |
@5000MHz | dB/100m | 245 |
@6000MHz | dB/100m | 277 |
Velocity of propagation | % | 70.7 |
Mechanical and Thermal Properties
Minimum Bending Radius : 5mm (static)
Temperature Range : -40℃~ +105℃
Technical Data
Conductor Construction | Nominal Inner Conductor Diameter | Nominal Outer Conductor Diameter | Nominal Overall Diameter | Nominal Weight |
|---|---|---|---|---|
No/mm | mm | mm | mm | kg/km |
0.54 | 2.5 | 3.16 | 21 |

Email Address: Li.wang@feichuncables.com