FRA 400 SW4

Application and Description

These cables are designed for flexible installations, inside and outside railway rolling stock.

Standards

DIN 5510-2

Construction

  • Inner conductor: Stranded silver plated copper

  • Insulation: Crosslink Foam PE (SPEX)

  • Outer conductor (shield 1): Silver plated copper

  • Outer conductor (shield 2): Silver plated copper

  • Sheath: LSZH Elastomer

Electrical Characteristics at 20℃

Impedance

Ω

50+/-2

Nominal Capacitance

pF/m

94.5

Minimum Insulation Resistance

MΩ.km

100000

Inner Conductor Resistance

MΩ/km

29.45

Outer Conductor Resistance

MΩ/km

7.6

Attenuation

 

 

@10MHz

dB/100m

5

@50MHz

dB/100m

11

@100MHz

dB/100m

16

@150MHz

dB/100m

20

@200MHz

dB/100m

23

@300MHz

dB/100m

29

@400MHz

dB/100m

34

@450MHz

dB/100m

36

@500MHz

dB/100m

38

@600MHz

dB/100m

42

@800MHz

dB/100m

50

@850MHz

dB/100m

51

@900MHz

dB/100m

53

@950MHz

dB/100m

55

@1000MHz

dB/100m

56

@1800MHz

dB/100m

79

@1900MHz

dB/100m

82

@2000MHz

dB/100m

84

@2400MHz

dB/100m

94

@3000MHz

dB/100m

107

@4000MHz

dB/100m

128

@5000MHz

dB/100m

147

@6000MHz

dB/100m

165

Velocity of propagation

%

70.7

Mechanical and Thermal Properties

Minimum Bending Radius

25mm (static)

Temperature Range

-40℃~ +105℃

Technical Data

Conductor Construction

Nominal Inner Conductor Diameter

Nominal Outer Conductor Diameter

Nominal Overall Diameter

Nominal Weight

No/mm

mm

mm

mm

kg/km

19/0.2

1.0

4.24

5.0

60