Anhui Feichun Special Cable Co.,Ltd Email: Li.wang@feichuncables.com

HIFLEX TOP-PVC
Rated voltage:Uo/U 350/0V
Test voltage:2000V
Insulation resistance at +20° C:≥:(+20°C):≧20MΩx km
Bending radius:
stationary :10 x cable diameterØ
flexible:10 x cable diameterØ
Temperature range:
flexible:-5°C - 70°C
stationary:-30°C - 80°C
Radiation resistance:≤80×10cJ/kg
Flame retardant:IEC 60332-1
Breakdown Voltage: min. 4000V
Coupling Resistance: ≤250 Ohm/km
Flame Retardant: Complies with VDE0482 Part 265-2-1/EN 50265-2-1/IEC 60332-1
Wire Color Identification (Based on the last two digits)
01 / 0.14 / gn/ye, gy/pk, bu/rd +0.5 / wh, bn
02 / 0.14 / gn/ye, gy/pk, bu/rd +0.5 / wh, bn
03 / 0.14 / gn/gy, pk/rd, bn/bk +0.5 / wh, bu, whgn, bngn
04 / 0.14 / rd/bk, bn/gn, ye/vt, gy/pk +0.5 / wh, bu, whgn, bngn
Material list
Part No. | No.cores Xcross-sec. | Outer Øca. | Cop.weight | Weight ca. |
|---|---|---|---|---|
315101 | (3x(2x0,14)+2x(0,5)) | 8,5 | 78,0 | 112 |
315102 | (3x(2x0,14)+2x0,5) | 8,5 | 72,0 | 108 |
315103 | (3x2x0,14+4x0,5) | 8,5 | 66,0 | 98 |
315104 | (4x2x0,14+4x0,5) | 8,5 | 68,0 | 111 |