HIFLEX Z-FD 0.6/1KV

Rated voltage:Uo/U 600/1000V

Test voltage:4000V

Insulation resistance at +20° C:≥:(+20°C):≧20MΩx km

Bending radius:

      stationary :4 x cable diameterØ

       flexible:7.5 x cable diameterØ

Temperature range:

       flexible:-5°C - 80°C

      stationary:-40°C - 80°C

Radiation resistance:≤80×10cJ/kg

Flame retardant:IEC 60332-1

Design: 

● Stranded bare Cu conductor, extra-fine wire

● Strand structure to VDE 0295,class 6 / IEC 60228 class 6

● Core insulation: special PVC

● Black cores with printed consecutive white number coding

● Green-yellow protective conductor

(3 cores and over) in the outer layer

● Cores twisted in layers, with optimal lay lengths

● Fabric lapping

● Outer sheath: special PVC, flame retardant

● Sheath colour: RAL 7001 grey

Applications: 

This cable is ideal for use on drag chains or as control cable for continuously moved machine components in dry and damp environments. Designed to resist up to mean mechanical bending loads.

When used for outdoor applications, adequate protection against direct exposure to sunlight must be ensured and the specified temperature limits must be observed.

  • Material list

Part No.

No.cores Xcross-sec.
mm²

Outer Øca.
mm

Cop.weight
kg / km

Weight ca.
kg / km

301201

4G1,5

9,6

58,0

130

301202

4G2,5

11,2

95,0

220

301203

4G4

13,0

154,0

330

301204

4G6

14,5

231,0

445

301205

4G10

18,2

384,0

660

301206

4G16

22,3

615,0

1060

301207

4G25

27,4

960,0

1805

301208

4G35

30,0

1344,0

2060

301209

4G50

35,8

1920,0

2900

301210

4G70

40,9

2640,0

4050

301211

4G95

46,2

3648,0

5540

301212

4G120

51,6

4608,0

7000